{"id":17972,"date":"2021-11-30T13:10:10","date_gmt":"2021-11-30T12:10:10","guid":{"rendered":"https:\/\/mecadi.com\/uncategorized\/test-sample-manufacture\/"},"modified":"2021-12-03T11:51:57","modified_gmt":"2021-12-03T10:51:57","slug":"test-sample-manufacture","status":"publish","type":"post","link":"https:\/\/www.mecadi.com\/en\/permeation-measurement\/test-sample-manufacture\/","title":{"rendered":"Test sample manifacture &#8211; Sample preparation for permeation measurement"},"content":{"rendered":"<h2>Process<\/h2>\n<p>From materials for which there are no test plates or films for permeation measurement, Mecadi makes the test samples itself.<\/p>\n<p>Examples: adhesives, castables.<\/p>\n<p>&nbsp;<\/p>\n<p>Possibilities at Mecadi:<\/p>\n<p>Sample preparation of thermally or UV-curing systems<br \/>(No die casting)<\/p>\n<h2>What do we need?<\/h2>\n<ul>\n<li>Approx. 20 ml (In case of 100 % solids) per pattern (Or after prior consultation)<\/li>\n<li>Data sheet of handling<\/li>\n<li>Safety Data Sheets<\/li>\n<\/ul>\n<h2>What do we do?<\/h2>\n<ul>\n<li>Selection of substrate depending on the desired permeation test (preferably permeable)<\/li>\n<li>Selection of substrate chemically compatible, non-absorbent<\/li>\n<li>Pretest coatability (wettability, film formation)<\/li>\n<li>Preparation of test samples\n<ul>\n<li>Thermal curing (up to 300\u00b0C), for example, chemically crosslinking or steam systems or UV-curing<\/li>\n<li>Also handling of 1K systems including cold storage (-18\u00b0C) possible<\/li>\n<li>1K\/2K-Systeme processible, also more complex mixtures<\/li>\n<li>Pretreatment: mixing, outgassing, filtering possible<\/li>\n<li>Layer thickness: according to requirements, typically &gt; 10\u00b5m up to several millimeters<\/li>\n<li>On carrier or carrier-free<\/li>\n<li>Lab coat: Coating knife, spiral coating knife, screen process, dip coating, spray, etc.<\/li>\n<li>Optical: Thin layers &lt; 10 \u00b5m under clean room \/ glovebox conditions<\/li>\n<\/ul>\n<\/li>\n<li>Characterization\n<ul>\n<li>Inspection for defects (dye test , optical, leakage testing using gas or liquids)<\/li>\n<li>Blanks<\/li>\n<li>Masking<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>-&gt; Use in permeation test<\/p>\n<h2>Costs:<\/h2>\n<p>Please ask for offer \/ project-specific according to expenditures<\/p>\n<h2>Materials:<\/h2>\n<ul>\n<li>Coatings (e.g. corrosion protection coatings)<\/li>\n<li>On carrier film (e.g. packaging films, elastomers, fluoropolymers, polymeric films such as PVC, PET, polyolefins, PE-metallocenes, copolymers)<\/li>\n<li>On porous carriers (membranes)<\/li>\n<li>On inspection sheets<\/li>\n<li>Adhesives (e.g. epoxides)<\/li>\n<li>Coatings (e.g. nano- coatings)<\/li>\n<li>Silicones (e.g. 1K silicones, 2K silicones)<\/li>\n<li>Casting compound<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Process From materials for which there are no test plates or films for permeation measurement, Mecadi makes the test samples itself. Examples: adhesives, castables. &nbsp; Possibilities at Mecadi: Sample preparation of thermally or UV-curing systems(No die casting) What do we need? Approx. 20 ml (In case of 100 % solids) per pattern (Or after prior&hellip;&nbsp;<a href=\"https:\/\/www.mecadi.com\/en\/permeation-measurement\/test-sample-manufacture\/\" rel=\"bookmark\">Read More &raquo;<span class=\"screen-reader-text\">Test sample manifacture &#8211; Sample preparation for permeation measurement<\/span><\/a><\/p>\n","protected":false},"author":4,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_yoast_wpseo_title":"Test sample manifacture - Sample preparation for permeation measurement","_yoast_wpseo_metadesc":"Test Sample Manufacture","neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","footnotes":""},"categories":[1633],"tags":[],"class_list":["post-17972","post","type-post","status-publish","format-standard","hentry","category-permeation-measurement"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.1.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Test sample manifacture - Sample preparation for permeation measurement<\/title>\n<meta name=\"description\" content=\"Test Sample Manufacture\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.mecadi.com\/en\/unkategorisiert\/test-sample-manufacture\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Test sample manifacture - Sample preparation for permeation measurement\" \/>\n<meta property=\"og:description\" content=\"Test Sample Manufacture\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.mecadi.com\/en\/unkategorisiert\/test-sample-manufacture\/\" \/>\n<meta property=\"og:site_name\" content=\"Permeation &amp; Polymers\" \/>\n<meta property=\"article:published_time\" content=\"2021-11-30T12:10:10+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-12-03T10:51:57+00:00\" \/>\n<meta name=\"author\" content=\"Mecadi\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Mecadi\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Test sample manifacture - Sample preparation for permeation measurement","description":"Test Sample Manufacture","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.mecadi.com\/en\/unkategorisiert\/test-sample-manufacture\/","og_locale":"en_US","og_type":"article","og_title":"Test sample manifacture - Sample preparation for permeation measurement","og_description":"Test Sample Manufacture","og_url":"https:\/\/www.mecadi.com\/en\/unkategorisiert\/test-sample-manufacture\/","og_site_name":"Permeation &amp; Polymers","article_published_time":"2021-11-30T12:10:10+00:00","article_modified_time":"2021-12-03T10:51:57+00:00","author":"Mecadi","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Mecadi","Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.mecadi.com\/en\/unkategorisiert\/test-sample-manufacture\/#article","isPartOf":{"@id":"https:\/\/www.mecadi.com\/en\/unkategorisiert\/test-sample-manufacture\/"},"author":{"name":"Mecadi","@id":"https:\/\/www.mecadi.com\/de\/#\/schema\/person\/66c077d6aa9e9d5e506aa9929a63ab47"},"headline":"Test sample manifacture &#8211; Sample preparation for permeation measurement","datePublished":"2021-11-30T12:10:10+00:00","dateModified":"2021-12-03T10:51:57+00:00","mainEntityOfPage":{"@id":"https:\/\/www.mecadi.com\/en\/unkategorisiert\/test-sample-manufacture\/"},"wordCount":256,"commentCount":0,"publisher":{"@id":"https:\/\/www.mecadi.com\/de\/#organization"},"articleSection":["Permeation Measurement"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.mecadi.com\/en\/unkategorisiert\/test-sample-manufacture\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.mecadi.com\/en\/unkategorisiert\/test-sample-manufacture\/","url":"https:\/\/www.mecadi.com\/en\/unkategorisiert\/test-sample-manufacture\/","name":"Test sample manifacture - Sample preparation for permeation measurement","isPartOf":{"@id":"https:\/\/www.mecadi.com\/de\/#website"},"datePublished":"2021-11-30T12:10:10+00:00","dateModified":"2021-12-03T10:51:57+00:00","description":"Test Sample Manufacture","breadcrumb":{"@id":"https:\/\/www.mecadi.com\/en\/unkategorisiert\/test-sample-manufacture\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.mecadi.com\/en\/unkategorisiert\/test-sample-manufacture\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.mecadi.com\/en\/unkategorisiert\/test-sample-manufacture\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.mecadi.com\/en\/permeation-polymers\/"},{"@type":"ListItem","position":2,"name":"Test sample manifacture &#8211; Sample preparation for permeation measurement"}]},{"@type":"WebSite","@id":"https:\/\/www.mecadi.com\/de\/#website","url":"https:\/\/www.mecadi.com\/de\/","name":"Permeation &amp; Polymers","description":"innovation for your business","publisher":{"@id":"https:\/\/www.mecadi.com\/de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.mecadi.com\/de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.mecadi.com\/de\/#organization","name":"Permeation &amp; Polymers","url":"https:\/\/www.mecadi.com\/de\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mecadi.com\/de\/#\/schema\/logo\/image\/","url":"https:\/\/www.mecadi.com\/wp-content\/uploads\/cropped-Logo_Mecadi_2025.png","contentUrl":"https:\/\/www.mecadi.com\/wp-content\/uploads\/cropped-Logo_Mecadi_2025.png","width":828,"height":439,"caption":"Permeation &amp; Polymers"},"image":{"@id":"https:\/\/www.mecadi.com\/de\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.mecadi.com\/de\/#\/schema\/person\/66c077d6aa9e9d5e506aa9929a63ab47","name":"Mecadi","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.mecadi.com\/de\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/9ad66aedc2b8075b694d07ba06b67d1f2f2248533d64a9b8925fd9192d696752?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/9ad66aedc2b8075b694d07ba06b67d1f2f2248533d64a9b8925fd9192d696752?s=96&d=mm&r=g","caption":"Mecadi"},"sameAs":["florian"],"url":"https:\/\/www.mecadi.com\/en\/author\/mecadi\/"}]}},"_links":{"self":[{"href":"https:\/\/www.mecadi.com\/en\/wp-json\/wp\/v2\/posts\/17972","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.mecadi.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.mecadi.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.mecadi.com\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.mecadi.com\/en\/wp-json\/wp\/v2\/comments?post=17972"}],"version-history":[{"count":1,"href":"https:\/\/www.mecadi.com\/en\/wp-json\/wp\/v2\/posts\/17972\/revisions"}],"predecessor-version":[{"id":20474,"href":"https:\/\/www.mecadi.com\/en\/wp-json\/wp\/v2\/posts\/17972\/revisions\/20474"}],"wp:attachment":[{"href":"https:\/\/www.mecadi.com\/en\/wp-json\/wp\/v2\/media?parent=17972"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.mecadi.com\/en\/wp-json\/wp\/v2\/categories?post=17972"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.mecadi.com\/en\/wp-json\/wp\/v2\/tags?post=17972"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}